Specifications
- Performance (at initial value)
- Contract resistance: 100mΩ max.
- Operate time: 15msec max., 20msec max.
- Release time: 8mesc max.
- Dielectric strength between coil & contract, between contracts: AC 5000V 50/60 Hz (1 min.); AC 1000V 50/60 Hz (1min.)
- Surge resistiveness: 10,000V (between coil and contact 1.2 x 50mA s.)
- Insulation resistance: 100mΩ min. (DC 500V)
- Max. on/off switching mechanically and electrically: 300 operations/min.; 30 operations/min.
- Operating ambient temperature: -30 to + 55 ℃; -30 to + 70 ℃ (no condensation of water drop)
- Operating humidity: 45 to 85% RH
- Coil temperature rise: 45 deg. Max.; 35 deg Max. (at rate coil voltage)
- Vibration endurance and error operation: 10 to 55Hz dual amplitude width 1.5mm; 10 to 55Hz dual amplitude width 1.5mm
- Shock endurance and error operation: 100G min; 10G min.
- Life expectancy mechanically and electrically: 10,000,000 operations/min.; 100,000 operations/min.
- Weight: 13g
- UL file no.: E58304
- CSA file no.: LR48471
- VDE file no.: 1814ug,6678
- Semko file no.: 9517235
- Contact rating:
- Contact capacity, resistive load (cos. φ = 1): AC 120V 5A, AC240V 5A, DC 24V 5A, AC 120V 2A, AC 240V 2A, DC 24V 2A
- Rated carrying current: 5A
- Maximum allowable voltage: DC 110V; AC 240V
- Maximum allowable current: 5A
- Maximum allowable power force: 600VA 150W
- Referential min. applicable load: DC 10V, 10mA
- Contact material: Agcdo
Features
- Switching capacity by 5 available with 2 transfer contact form.
- Slim type and small occupying area can offer high density P.C. board technique.
- Insulation distance of 8mm min, is designed. By employment of insulation material to meet JIS insulation class E, dielectric strength of 5000V min. and surge resistiveness 10000V min., is realized.
- Conforming to UL, CSA, VDE, SEMKO, J.A.M.C.L.
- Low coil power consumption type of OMI-L and general coil power consumption type of OMI-D are prepared to comply with user's wide selection.
- Employment of suitable plastic materials to be applied to high temperature and various chemical solution.
- Complete sealed type available if required.
- Application, Cooking Appliances, Air Conditioners, Audio Equipment, Domestic Appliances, Controlling Equipment, etc.
Coil sensitivity (at 20 Celsius) | Coil voltage code (at 20 Celsius) | Nominal voltage code (VDC) (at 20 Celsius) | Nominal current (mA) (at 20 Celsius) | Coil resistance ohm +/- 10% (at 20 Celsius) | Power consumption (W)(at 20 Celsius) | Pull-in voltage (VDC) (at 20 Celsius) | Drop-out voltage (VDC) (at 20 Celsius) | Max-allowable voltage (VDC) (at 20 Celsius) |
---|---|---|---|---|---|---|---|---|
OMI-D | 03 | 3 | 240 | 12.5 | Abt. 0.72 | 75% max | .10% min | .130% |
OMI-D | 05 | 5 | 138.9 | 36 | Abt. 0.72 | 75% max | .10% min | .130% |
OMI-D | 06 | 6 | 120 | 50 | Abt. 0.72 | 75% max | .10% min | .130% |
OMI-D | 09 | 9 | 78.3 | 115 | Abt. 0.72 | 75% max | .10% min | .130% |
OMI-D | 12 | 12 | 60 | 200 | Abt. 0.72 | 75% max | .10% min | .130% |
OMI-D | 24 | 24 | 29.3 | 820 | Abt. 0.72 | 75% max | .10% min | .130% |
OMI-D | 48 | 48 | 14.5 | 3,300 | Abt. 0.72 | 75% max | .10% min | .130% |
OMI-L | 03 | 3 | 176.5 | 17 | Abt. 0.54 | 80% max | .10% min | .130% |
OMI-L | 05 | 5 | 106.4 | 50 | Abt. 0.54 | 80% max | .10% min | .130% |
OMI-L | 06 | 6 | 88 | 68 | Abt. 0.54 | 80% max | .10% min | .130% |
OMI-L | 09 | 9 | 58 | 155 | Abt. 0.54 | 80% max | .10% min | .130% |
OMI-L | 12 | 12 | 44.4 | 270 | Abt. 0.54 | 80% max | .10% min | .130% |
OMI-L | 24 | 24 | 21.8 | 1,100 | Abt. 0.54 | 80% max | .10% min | .130% |
OMI-L | 48 | 48 | 10.9 | 4,400 | Abt. 0.54 | 80% max | .10% min | .130% |
Main Products
general purpose relays, automotive relays, telecom relays, solid state input / output modules, time delay relays, circuit breakers