The infrared rays emitted from the transmitter are reflected in the direction of incidence and then enter the receiver. A protector loop is formed in the route of transmitter to reflector, back to receiver. Whenever this loop is interrupted, it is detected and alarm is initiated.
Specifications
- Alarm distance: 5m
- Infrared beam: 500Hz
- Response time: 100msec
- Supply Voltage: DC11~20V
- Power consumption: 30mA
- Alarm signal: Non-Voltage Contact 1a, 1b (24 VDC/1A)
- Operating temperature: -20 ~ 50 Celsius
- Weight: 95g
Features
- Protection range: 5 meters
- Both models mount with a standard signal gang electric box
- Excellent external light immunity
- LED alignment indicator-visibly confirms proper alignment
- Beam protection for entrances, exits, corridors and staircases
- Detection method: Infrared photoelectric
- LED indicator: Red LED on in alarm condition
- Connection: Lead wire