Products
  • Products
  • Suppliers
  • Categories

Photoelectric Detector

Product ID: 3H-2451

Send Inquiry
3H plug-in detectors are specifically designed to meet the stringent performance requirements of industrial and commercial fire detection/alarm systems. The design of these detectors emphasizes ease of installation and field maintenance. 3H 400 series(TM) plug-in smoke detectors are designed to meet the performance criteria designated by UL/ULC. The ion and photo units have a sensing chamber sealed from back pressure air flow, dirt, and insects. This chamber is protected by a fine mesh screen which can be cleaned or replaced. Additional key features include a recess mounting option, interchangeable ion, photo, or thermal detectors, a variety of mounting bases, and full line of optional accessories. All 400 series(TM) Photoelectric smoke detectors contain an optical sensing chamber designed to sense the presence of smoke particles produced by a wide range of combustion sources. A custom integrated circuit incorporates signal processing to reduce false alarms.
Specifications
  • Operating voltage/alarm current: mounting base dependent
  • Standby current:
    • Photo/ion: 100uA maximum
    • Thermal: 120uA maximum
  • Sensitivity: 1.9%+/-. 6%/ft. Ion; 3.0%+/-. 7%/ft. Photo
  • Weight: 0.5lb.(277gm)
  • Size: 3.2"/8.1cm h.; 4.0"/10.2cm dia. unflanged base; 6.2"/15.8cm dia. flanged base
  • Construction: flame retardant Noryl plastic
  • Operating temperature: 32 Fahrenheit to 100 Fahrenheit(0 Celsius to 38 Celsius)
  • Alarm point thermal: 135 Fahrenheit(57.6 Celsius) or 15 Fahrenheit/min. rate of rise
  • Humidity range: 10-93%RH non-condensing
  • Air velocity rating: 3000fpm max.
  • Smoke detector spacing:
    • For ion, photo, and photo/thermal detectors on smooth ceilings(as defined in NFPA 72), spacing of 30 feet(900sq. ft) may be used as a guide.
    • For thermal detectors on smooth ceiling(as defined in NFPA 72), spacing of 50 feet(2500 sq. ft.) may be used.
    • Other spacing may be used depending on ceiling height, high air movements, and other conditions or response requirements.
Features
  • Low standby current
  • Two visible LEDs "blink" in standby and provide a 360 Degrees field viewing angle
  • Broad variety of mounting bases
  • Easy plug-in of the head to base
  • Field metering of detector sensitivity
  • Field adjustable sensitivity
  • Built-in test switch
  • Built-in tamper-resistant feature
  • Designed for direct surface or electrical box mounting
  • SEMS screws for easy wiring
  • Optional recess mounting
  • Removable cover and insect screen for field cleaning
Base model number Version Loop type Current limit resistor Alarm contact type Nominal voltage Current drew on alarm(mA)
B401B UL/ULC 2-wire No N/A 12/24VDC++ 10-100
B401BR UL/ULC 2-wire Yes N/A 24VDC 10-62
B402B UL/ULC 4-wire Yes Form A & C 24VDC 14-39
B404B UL/ULC 4-wire Yes Form A & C + A supply 120VAC 75mA AC Max
B406B UL/ULC/EN-54 2-wire No Form C 24VDC 12-100
B401+ UL/EN-54 2-wire No N/A 12/24VDC++ 10-100
B401R+ EN-54 2-wire Yes N/A 24VDC 10-62

Main Products

fire protection equipment including sprinkling system, ABC dry powder fire extinguishing agent, fire alarm system control panel, fire fighting system