Laboratory Water Hardness Meter
There is a microprocessor chip inside the meter conform to international GLP function, the appearance of meter looks beautiful and easily using.
For notable features read as follows:
1. Adopts 601-F water hardness combination electrode which consists of measuring electrode, reference electrode and temperature probe. At the same time, its new structure, stable electrode potential, quick response and use easily features are more welcomed by customers.
2. The electronic unit adopts intelligent chip design, which has automatic calibration, automatic temperature compensation, data storage; measuring value can be locked automatically and automatic power off and low potential displaying function etc.
3. Eight water hardness units can be chosen freely: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler), mg/L (Ca), ◦fH (France Degree), ◦dH (German Degree) and ◦eH (England Degree), which can choose in the WH-Link communication software.
4. It adopts digital filter and step slipping technology to intelligently improve meter’s response speed and result accuracy. “ ” will appear when reading is stable.
5. Equips B1, B2 and B3 three calibration solutions.
6. LCD display with blue background.
7. Equips WH-Link communication software which can transput the data to computer.
8. Meter’s circuit board adopts SMT film-covering technology to improve meter’s production reliability.
For notable features read as follows:
1. Adopts 601-F water hardness combination electrode which consists of measuring electrode, reference electrode and temperature probe. At the same time, its new structure, stable electrode potential, quick response and use easily features are more welcomed by customers.
2. The electronic unit adopts intelligent chip design, which has automatic calibration, automatic temperature compensation, data storage; measuring value can be locked automatically and automatic power off and low potential displaying function etc.
3. Eight water hardness units can be chosen freely: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler), mg/L (Ca), ◦fH (France Degree), ◦dH (German Degree) and ◦eH (England Degree), which can choose in the WH-Link communication software.
4. It adopts digital filter and step slipping technology to intelligently improve meter’s response speed and result accuracy. “ ” will appear when reading is stable.
5. Equips B1, B2 and B3 three calibration solutions.
6. LCD display with blue background.
7. Equips WH-Link communication software which can transput the data to computer.
8. Meter’s circuit board adopts SMT film-covering technology to improve meter’s production reliability.