Products
  • Products
  • Suppliers
  • Categories

Multi-parameter Patient Monitor

Product ID: UT6000A

Send Inquiry
7″Color TFT Display;
Big font display;
4-channel Waveform Display (2ECG Channel)
600 - set Blood Pressure Data Storage and Recall;
48 hours Trend information;
Power-off Storage
Pacemaker Detection and Apnea Alarm
1 Minute Full Waveform Recall
Manual/Auto/STAT Measurement of Blood Pressure, Programmable cycle 1 minute to 120 minutes;
Applications from Neonate to Adult;
Networking Capability
AC/DC Operation
Specifications
  • ECG:
    • Heart Rate Range: 15 - 300bpm(?bpm)
  • Lead Selection: Ⅰ,Ⅱ,Ⅲ, or Ⅰ,Ⅱ,Ⅲ, aVR, aVL, aVF, V
  • Lead Fault Alarm: Audible and Visual
  • Sweep Speed: 12.5/25/50mm/sec
  • Gain Selection: ?, ? ? ?.5 ?.25, Auto
  • ECG Calibration: 1mV
  • ST range: -0.8 - +0.8mV
  • Protection: Against electrosurgical interference and
  • defibrillation
    • NIBP
      • Method: Automatic Oscillometry
    • Parameters: SYS/DIA/MAP
    • Operating Modes: Manual/Auto/STAT
    • Scale: mmHg/kPa
    • Systolic: Adult/pediatric 30 - 254mmHg
    • Neonate 30 - 135mmHg
    • Diastolic: Adult/pediatric 10 - 220mmHg
    • Neonate 10 - 110mmHg
    • Cuff Pressure Range: Adult/pediatric 0 - 280mmHg
    • Neonate 0 - 150mmHg
      • SPO2
        • Saturation Range: 0 - 100%
      • Accuracy: ?%(70-100%), ?%(50 - 69%)
      • Pulse Rate Range: 30-254bpm
      • Pulse Rate Accuracy: ?%(30 - 100bpm), ?%(>100bpm)
      • SPO2 Averaging: 8 - beat average
      • Sensor Types: Finger clip, universal "Y", wrap, ear
        • Respiration ( RESP)
          • Measurement method: Thoracic impedance
        • Respiration rate range: 0 - 150 brpm?brpm
        • Waveform speed: 6.25, 12.5, 25mm/sec
          • Temperature (TEMP)
            • Measurement and alarm range: 0 - 50℃
          • Channel: Temp1 and Temp2
          • Probe: Skin sufface or Rectal/Esophageal
          • Scale: Celsius/Fahrenheit
          • Accuracy: 得.1℃
          • Resolution: o.1℃
Features
  • Big font display;
    • 7″Color TFT Display;
  • 4-channel Waveform Display (2ECG Channel)
    • Power-off Storage
      • 600 - set Blood Pressure Data Storage and Recall;
    • 48 hours Trend information;
      • 1 Minute Full Waveform Recall
        • Pacemaker Detection and Apnea Alarm
      • Manual/Auto/STAT Measurement of Blood Pressure, Programmable cycle 1 minute to 120 minutes;
        • Applications from Neonate to Adult;
        • Networking Capability
        • AC/DC Operation
Certificate
  • High

Main Products

multi-parameter patient monitors,Digital Video Colposcopes